Auction Closes

Thursday, 2021-11-25 10:13 UTC+01:00

Auction ended

Add to calendar
Add to Google Calendar Add to Apple Calendar Add to Outlook

You can add a reminder in your calendar before the auction ends

Have any questions about the item?

Thomas Brandt

Air sampling system Millipore

  • 849578
  • 75228 Uppsala

A sustainable action

The climate footprint of a corresponding newly produced item is approx 5121kg CO2 Click here to find out more

Info Shipping Exhibition Pick up Auction type
Brand Millipore
Model MAS-100 NT

MAS-100 NT® is our precise, fully validated and ISO14698 compliant air sampler. Also available as MAS-100 NT® Ex for use in explosion hazard areas. A wide range of accessories is also available.

Overview

The new MAS-100 NT® is arguably the most precise, most reliable and most cost-effective air sampler system available today - a solution you can rely on to detect any airborne micro-organisms which may be hazardous to your products. Developed in close cooperation with specialists in the pharmaceutical industry, this high-precision air sampler system is very easy to handle, delivers correct and reproducible results, and fully complies with the EN ISO 14698 standard parts 1 and 2. It is an improved version of our very successful MAS-100® Air Sampler System that has been highly appreciated for years by even the most demanding customers in the pharmaceutical industry.

The benefits of our MAS-100 NT® are compelling:

 

  • Precise, reproducible measurements
  • High collection efficiency
  • Built-in air flow compensation
  • Compatible with standard 90 mm Petri dishes and 60 mm contact plates
  • Hardware and software validated for HACCP
  • Validation documents according to ISO 14698

 

Proven and improved microbial air monitoring

The original MAS-100® was a unique achievement and an incredible success - but the new MAS-100 NT® is even better. Its compact, user-friendly design, improved security features, easy and fully automatic calibration, validated software, and enhanced connection options make the MAS-100 NT® Active Microbial Air Sampler truly unique:

  • Improved design with an illuminated display for easy navigation
  • Improved HACCP software with Microsoft Windows log-in functionality and reporting
  • Menu in a variety of languages (English, French and German; Spanish in preparation, others on demand)
  • Acoustic alarm feature
  • Data logging for samples and alarms
  • Communication via USB port for error-free result transmission and automatic record-keeping
  • Long-life lithium ion batteries with intelligent recharging feature, and much more.


All functions and parameters as well as the calibration procedure can be controlled using the MAS-100 NT® software or may be programmed directly on the unit. Alarms and samples are logged and the last 100 events recorded. These can be exported or printed at any time. Hardware and software have been developed according to GAMP4.

 

Based on the Andersen impactor

The MAS-100 NT® Active Microbial Air Monitoring System is a high-performance instrument based on the Andersen air sampler: Air is aspirated through a perforated lid and impacted onto the surface of growth media in a standard 90 mm Petri dish or 60 mm contact plate. Micro-organisms are trapped on the culture media, and after the incubation period the formed colonies can be counted.

Highest sample collection accuracy

No other microbial air monitoring system is as accurate in collecting samples as the MAS-100 NT®. Compared with its predecessor, the MAS-100®, impaction speed on the MAS-100 NT® - and thus its collection efficiency - has been further improved, thanks to a new sampling head with 300 x 0.6mm holes. The system uses a state-of-the-art mass flow sensor to measure the inflow of air and to continuously regulate the aspirated air volume during sample collection to maintain a constant value of 100 liters / min. This allows the MAS-100 NT® System to automatically adjust for differences in fill volumes of Petri dishes, changes in air density, and differences between individual perforated lids.

MAS-100®: The most complete and accurate line of microbial air monitoring systems available

The new MAS-100 NT® is part of the comprehensive MAS-100® product family. In addition to the high-precision air sampler MAS-100 NT®, this line of microbial air monitoring systems comprises the MAS-100 NT Ex®, a derivative of MAS-100® for use in explosion risk areas, the MAS-100 Eco ®, a cost-efficient, flexible and more basic instrument designed for the food and environment industries, the MAS-100 CG Ex® for testing all types of compressed gases used in industry, and the DA-100 NT® Digital Anemometer for the calibration of MAS-100 NT® Systems (with the exception of the MAS-100 CG Ex®).

MAS-100 NT® microbial air sampler with air outlet particle filter for ultra-sensitive areas and cleanrooms

Eliminate the risk of cleanroom cross-contamination
Viable air samplers are used for quantitative determination of airborne contamination in cleanrooms and insulators. To maintain the cleanliness of the environment, the air flow should neither disturb the unidirectional air flow nor pose a contamination risk to the environment.
As portable air samplers are sometimes moved and used in various environments with different levels of microbial contamination, there might be a risk of cross-contamination from higher to low contaminated environments.

Microbial air sampling in ISO class 5 GMP grade A environments
The MAS-100 NT® is specified for use in ISO Class 5 / GMP Grade A environments and is equipped with a brushless motor which generates a minimal quantity of particles, so that no filter is required even for GMP Grade A usage. If instruments are used in different cleanroom classes, there is a minor risk that particles may be carried over inside an instrument. In this case, a HEPA H13 exhaust air particle filter can be mounted to give you peace of mind.

Eliminate particle carry-over using our MAS-100 NT ® viable air sampler with HEPA air exhaust filter
To prevent any potential transfer of particles from inside the instrument, an air outlet filter adapter was developed to add a HEPA H13 filter to the exhaust. The filter has no significant influence on the airflow calibration and therefore on the microbial sampling efficiency. In addition, stressing the filter for a simulated year of heavy usage in an uncontrolled environment does not reduce the filtration efficiency and will not clog the filter.

Important info

All bids are binding and the service fee is charged on all items. Any deviations from equivalent second-hand goods are described under the section Remarks in the description of the Item and thus PS is not responsible for the deviation.
The item is NOT TESTED by the auction firm unless otherwise specified in the object description. The object description is done with the best of our knowledge but not binding in detail.
PLEASE NOTE! Any pallet and pallet accessories seen in the picture are not included unless otherwise stated in the description.

If you want transportation assistance (only within Sweden), contact the handler in charge.

No view scheduled for this item.

Monday 29 November 2021 09:00 - 12:00 UTC+01:00

Vallongatan 1 75228 Uppsala

Important info

Payment must have been received by us before you can pick up the goods, so pay in time. 
Invoice copy and proof of payment must be brought to the pick up. The buyer shall at the appointed time arrange collection, loading, disassembly / packing of the item.

Regarding items in PS premises that have not been picked up on time PS have the right to charge 2500 SEK excl VAT / week per item

PLEASE NOTE! Any pallet and pallet accessories seen in the picture are not included unless otherwise stated in the description.

Disposal

Disposal means that a client has goods that they wish to sell. For example, it may be a supply / storage that is needs to be emptied, or that the company has restructured and does not need office space / equipment / etc anymore. This differs from bankruptcy since it's a voluntary sale.